  1. Grease on new Siemens circ. breaker contacts - need to wipe out …

    Aug 13, 2013 · Lately in the stores I found Siemens circuit breakers with some sort of grease, paste on the contacts. Just curious if this needs to be kept and install breaker in to panle with that or just wipe …

  2. Which breakers for SN4040B1200 - Love Plumbing & Remodel

    Apr 10, 2021 · Does anyone know which would be the best breakers to use in a Siemens SN4040B1200 panel? Will need a mix of arcfault, tanden and double-pole (220) breakers. Thank you!

  3. Two pole arc fault breakers for multi wire circuits

    Jan 6, 2014 · Arc fault breakers have earned a reputation for being finicky and trip happy, and all the while being difficult to troubleshoot. Possibly that is overblown. Hopefully, now that the technology is …

  4. "retainers" for breakers? - Love Plumbing & Remodel

    Feb 9, 2008 · Why does the main have four breakers? That is NOT four breakers. It's two 2-pole 100A breakers mounted in parallel creating a 2-pole 200A main breaker. Very common thing to see in …

  5. 6 AWG to 100 amp subpanel? - Love Plumbing & Remodel

    Nov 13, 2011 · I'm installing a sub-panel for a new addition. My load calc suggests a 50amp load for the sub-panel. So, I'm planning a 50amp feeder breaker in the main panel with #6 feeder wire to the sub …

  6. Navien Tripping Breaker - Love Plumbing & Remodel

    Jan 3, 2024 · My unit keeps tripping my Siemens 40amp breaker. There are a number of things on the line, but nowhere near 40 Amps. I changed my outlet to a gfci. I changed my 40amp breaker. Ive had …

  7. 200 amp service split between two panels - Love Plumbing & Remodel

    Mar 14, 2016 · for the 200 amp, 40 space panel (Siemens G4040B1200CU) that had its main breaker removed anda 100 amp backfed main installed on the bus: if its feeder wire is between #1 AWG - …

  8. Adding additional breakers to main panel instead of sub panel?

    Apr 4, 2017 · 1. If I add breakers to the main panel, there would now be these breakers in the panel: 1x 200 amp breaker 1x 50 amp breaker 3x 20 amp breaker So those extra breakers would be in parallel …

  9. Odd residential tied-breaker setup for 120v branch circuits

    Apr 7, 2024 · I see six circuits that have breakers that are handle-tied (see pics). I do not find a sub-panel where these would be split out to individual branch circuits, and the longest run from these …

  10. GFI trips on new circuit - Love Plumbing & Remodel

    Mar 4, 2017 · (Although both its lights come on indicating arc fault and ground fault…) (This is a siemens box, with siemens breakers.) Any advise about why the GFI might be tripping? I read that they will …